NOTES: 1. WE must be high during address transitions. 2. The internal write time of the memory is defined by the overlap of CE2, CEl and WE low. All signals must be active to initiate a write and any one signal can terminate a write by going inactive. The data input setup and hold timing should be referenced to the second transition edge of the signal that terminates the write. 3. TWRiS measured from the earlier of CE2 going low, or CEl or WE going high at the end of write cycle. 4. During this period, DQ pins are in the output state so that the input signals of opposite phase to the outputs must not be applied. 5. If the CE2 high transition or CEl low transition occurs simultaneously with the WE low transitions or after the WE transition, output remain in a high impedance state. 6. OE is continuously low (OE = VIL ). 7. Dou r iS the same phase of write data of this write cycle. 8. DOUT is the read data of next address. 9. If CE2 is high or CEl is low during this period, DQ pins are in the output state. Then the data input signals of opposite phase to the outputs must not be applied to them. 10. Transition is measured+500mV from steady state with CL = 5pF as shown in Figure lB. The parameter is guaranteed but not 100% tested. 11. Tcw iS measured from the later of CE2 going high or CEl going low to the end of write.
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso- lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations section of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
| | Re sis tive | Inductive |
| Rated load | lOA@250VAC/30VDC, | 7Af 250V AC/ 30V DC |
| Rated current' | 10A |
| Maximum switching voltage | 250V AC/ 125V DC |
| Maximum switching capacity | 2500VA. 300W 30V DC, 50W @ 125V DC 1750VA, 210W @ 30V DC. 35W @ 125V DC |
| Minimum switching capacity | 4V 25mA, 100V ImA |
| Contact resistance (initial) | 30m - 100m 3 |
| Operate time | 20m sec max |
| Rele ase time | 20m see max |
| Maximum operate frequency | 1800 0psihr at maximum rated load |
| Insulation class | Group B250 (according to DIN VDE0110) |
| Diele ctric s tre n gth (Coil - C,ontact) (Between adjacent Contacts) (Contact Gap) | 2500V AC 501 60 Hz for l minute 2000V AC 501 60 Hz for l minute 1000V AC 501 60 Hz for l minute |
| Ambient operating temperaturesi | -40 to+ 70C |
| Mechanical service life | 20 million ops mmimum |
| Electrical service life[ | 100,000 0ps at rated load |
| Protection degree | LP10 |
| Contact material | AgCdOiAu 0.2um |
| Voltage range | 80 - 110% |
| Must release voltage | 15%AC coil/ 10%DC coil |
| Power consumption | 2.5 VA AC l.35 watts DC |
| Coil wire clas s | F (1550C) |
| | |