| | | | LIMITS | |
| SYMBOL | PARAMETER | TEST CONDITIONS | 40YC to +85YC | 40YC to +125IC | UNIT |
| MIN | TYPi | MAX | MIN | MAX |
| | | Vcc= 1.2 V | 0 9 | | | 0 9 | | V |
| HIGH level Input | Vcc= 2.0V | 1 4 | | | 1 4 | |
| VIH | voltage | Vcc = 2.7 t0 3.6 V | 2 0 | | | 2 0 | |
| Vcc = 4.5 t0 5.5 V | 0.7Vcc | | | 0.7Vcc | |
| | | Vcc= 1.2 V | | | O3 | | 0.3 | V |
| LOW levellnput | Vcc= 2.0V | | | O6 | | 0.6 |
| VIL | voltage | Vcc = 2.7 t0 3.6 V | | | O8 | | 0.8 |
| Vcc= 4.5 t0 5.5 | | | 0.3Vcc | | 0.3Vcc |
| | | Vcc = 1.2 V; Vi = VIH or VIL; -10 = 100D:A | | 1.2 | | | | V |
| Vcc = 2.0 V; Vi = VIH or VIL; -10 = 100D:A | 1 8 | 2.0 | | 1 8 | |
| VOH | HIGH leve voltage; a | output outputs | Vcc = 2.7 V; VI = VIH or VIL; -10 = 100D:A | 2 5 | 2.7 | | 2 5 | |
| | Vcc = 3.0 V; Vi = VIH or VIL; -10 = 100D:A | 2 8 | 3.0 | | 2 8 | |
| Vcc = 4.5 V; Vi = VIH or VIL; -10 = 100D:A | 4 3 | 4.5 | | 4 3 | |
| | HIGH level output | Vcc = 3.0 V; Vi = VIH or VIL; -10 = 6mA | 2 40 | 2.82 | | 2 20 | | V |
| VOH | voltage; STANDARD outputs | Vcc = 4.5 V; Vi = VIH or VIL; -10 = 12mA | 3 60 | 4.20 | | 3 50 | |
| | | Vcc = 1.2 V; Vi = VIH or VIL; 10 = 100ccA | | O | | | | V |
| Vcc = 2.0 V; Vi = VIH or VIL; 10 = 100ccA | | O | O2 | | 0.2 |
| VOL | LOW level output | Vcc = 2.7 V; VI = VIH or VIL; 10 = 100ccA | | O | O2 | | 0.2 |
| voltage; all outputs | Vcc = 3.0 V; Vi = VIH or VIL; 10 = 100ccA | | O | O2 | | 0.2 |
| Vcc = 4.5 V; Vi = VIH or VIL; 10 = 100ccA | | O | O2 | | 0.2 |
| | LOW level output | Vcc = 3.0 V; Vi = VIH or VIL; 10 = 6mA | | O25 | 0.40 | | 0 50 | V |
| VOL | voltage; STANDARD outputs | Vcc = 4.5 V; Vi = VIH or VIL; 10 = 12mA | | O35 | 0.55 | | 0 65 |
| Il | Input leakage current | Vcc = 5.5 V; VI = Vcc or GND | | | 1.0 | | 1.0 | ccA |
| lcc | Quiescent supply current; MSI | Vcc = 5.5 V; VI = Vcc or GND; lo = 0 | | | 20 0 | | 160 | ccA |
| Clcc | Additional quiescent supply current per input | Vcc = 2.7 V t0 3.6 V; Vi = Vcc - 0.6 V | | | 500 | | 850 | ccA |
| | | | | | | | | |