| Parameter | Symbol | Conditions | min | typ | max | Unit |
| Current drain | lcc | When 6 V DC is applied to TPl, TP3 and TP5, and 9 V is applied to TP7 | 1.9 | 2 2 | 2 7 | mA |
| Minimum reference voltage | VREF min | Reference value | 0 | | | V |
| Maximum reference voltage | VREF max | Reference value | | | 75 | V |
| | VOUT min (R) | | | | 0 3 | V |
| Minimum output voltage | VOUT min (G) | When 12 V DC is applied to TPl, TP3 and | | | 0 3 | V |
| VOUT min (B) | TP5, and 9 V is applied to TP7 | | | 0 3 | V |
| | VOUT max (R) | | 77 | | | V |
| Maximum output voltage | VOUT max (G) | When o V DC is applied to TPl, TP3 and | 77 | | | V |
| VOUT max (B) | TP5, and 9 V is applied to TP7 | 77 | | | V |
| | VOUT high (R) | | 67 | 69 | 71 | V |
| High-Ievel output voltage | VOUT high (G) | When 3 V DC is applied to TPl, TP3 and | 67 | 69 | 71 | V |
| VOUT high (B) | TP5, and 9 V is applied to TP7 | 67 | 69 | 71 | V |
| | VOUT mid (R) | | 37 | 39 | 41 | V |
| Mid-Ievel output voltage | VOUT mid (G) | When 6 V DC is applied to TPl, TP3 and | 37 | 39 | 41 | V |
| VOUT mid (B) | TP5, and 9 V is applied to TP7 | 37 | 39 | 41 | V |
| | VOUT low (R) | | 7 | 9 | 11 | V |
| Low-Ievel output voltage | VOUT low (G) | When 9 V DC is applied to TPl, TP3 and | 7 | 9 | 11 | V |
| VOUT low (B) | TP5, and 9 V is applied to TP7 | 7 | 9 | 11 | V |
| | | | | | |